热门站点| 世界资料网 | 专利资料网 | 世界资料网论坛
收藏本站| 设为首页| 首页

JIS X5101-1982 数据电路端接设备与数据终端设备间的接口(25插针接口)

作者:标准资料网 时间:2024-05-15 01:49:57  浏览:9475   来源:标准资料网
下载地址: 点击此处下载
【英文标准名称】:TheInterfacebetweenDataCircuitTerminatingEquipment(DCE)andDataTerminalEquipment(DTE)(25-pinInterface)
【原文标准名称】:数据电路端接设备与数据终端设备间的接口(25插针接口)
【标准号】:JISX5101-1982
【标准状态】:现行
【国别】:日本
【发布日期】:1982-02-01
【实施或试行日期】:
【发布单位】:日本工业标准调查会(JP-JISC)
【起草单位】:TechnicalCommitteeonInformationTechnology
【标准类型】:()
【标准水平】:()
【中文主题词】:控制信号;数据处理设备;计算机终端;界面
【英文主题词】:interfaces;controlsignals;dataprocessingequipment;computerterminals
【摘要】:この規格は,デーク回線終端装置(DCE)とデータ端末装置(DTE)との間で,2進データ,制御信号及びタイミソダ信号を転送するための25ビンコネクタを用いるイソタプ=ースについて規定する。
【中国标准分类号】:L78
【国际标准分类号】:35_100_10
【页数】:16P;A4
【正文语种】:日语


下载地址: 点击此处下载
Product Code:SAE AMS7320
Title:Rings, Sealing, Cast Leaded-Tin Bronze, 80Cu - 16Sn - 5Pb, As Cast
Issuing Committee:Ams D Nonferrous Alloys Committee
Scope:This specification covers a cast leaded-tin bronze in the form of sealing rings.【英文标准名称】:Floodprotectionproducts-Specification-Buildingapertureproducts
【原文标准名称】:防洪产品.规范.建筑孔径产品
【标准号】:BSPAS1188-1-2009
【标准状态】:现行
【国别】:英国
【发布日期】:2009-04-30
【实施或试行日期】:2009-04-30
【发布单位】:英国标准学会(GB-BSI)
【起草单位】:BSI
【标准类型】:()
【标准水平】:()
【中文主题词】:物障;气候危害;名称与符号;尺寸规格;门;洪水;流量测量;建筑防灾;孔;检验;漏泄试验;作标记;开孔(建筑);质量控制;记录品(文献);安全性装置;密封材料;窗
【英文主题词】:Barriers;Climatichazards;Designations;Dimensions;Doors;Floods;Flowmeasurement;Hazardpreventioninbuildings;Holes;Inspection;Leaktests;Marking;Openings(constructionspaces);Qualitycontrol;Records(documents);Safetydevices;Sealingmaterials;Windows
【摘要】:ThisPASspecifiesrequirementsforthedesignation,testing,factoryproductioncontrol,installationdocumentationandmarkingfordifferenttypesandconfigurationsoffloodprotectionproducts.ThisPASisapplicabletofloodprotectionproductsintendedforuseinthetemporarysealingofbuildingaperturesandentrancestoproperties,intheeventofstaticfloodwaterrisinguptoalevelbetween600mmand900mmabovegroundlevel,exceptwheretheyaredesignedtocompletelycoverorreplacesmallapertures,suchasair-bricksorairvents.ThisPASisintendedforuseintheUKorlocationswithsimilarexposures,i.e.wherethereisatemperateclimateandadvancedwarningoffloodingisavailable.ThisPASspecifiesthemethodoftestingandanallowableleakagerate.Therangeofbuildingaperturesizescoveredisanominalwidthofupto2400mm.NOTE1Thehydrostaticpressuresexertedbyfloodwatercancausesuddenorlong-termstructuraldamageandunderminethefoundationsofabuildingorcauseleakagethroughthewalls,floororsub-floor,unlessthebuildingisspecificallydesignedtowithstandsuchstresses.Theactualwaterlevelthatcanbesafelyretainedbytheexternalwallswilldependupontheconstruction,type,form,ageandconditionofthewalls.Itisrecommendedthatasuitablyqualifiedbuildingsurveyor,architectorstructuralengineerinspectstheexternalwalls,beforeanyfloodprotectionproductforbuildingaperturesisinstalled.NOTE2Floodprotectionproductsarenotnormallyintendedtopreventwatermorethan600mmto900mmabovethelevelofthegroundsurroundingthepropertyfromenteringthebuilding.NOTE3ThePAStestconditionsrepresenttypicalconditionsthatcanbeexperiencedduringaflood.Thisincludestestingthefloodprotectionproductforleakageunderstaticwaterlevels,wavesupto0.1mhighandparallelcurrentsupto1.0m/s.NOTE4ThisPASdoesnotcovertestingwithcontaminatedorsalinewater,however,productmanufacturersarerequiredtoprovideinformationabouttheperformanceoftheirproductsintheseconditions(seeAnnexC).NOTE5Conformanceofthefloodprotectionproductdoesnotmeanitissuitableforallsituations.IftheuserisinanydoubtastothesuitabilityofafloodprotectionproducttheyshouldseekfurtherguidanceassetoutinPreparingforfloods:Interimguidanceforimprovingthefloodresistanceofdomesticandsmallbusinessproperties[1],orfromtheFloodProtectionAssociation(www.floodprotectionassociation.org)orotherprofessionaladvisers.NOTE6ExtremeloadingconditionssuchasthoseresultingfromturbulentwaterorfromdebrisimpactarenotcoveredbytestinginthisPAS.Ifrequiredintheselocations,thefloodprotectionproductneedstobespecificallydesignedand/ortestedtowithstandsuchstresses.NOTE7ThefloodprotectionproductsdescribedinthispartofPAS1188arenotintendedforinstallationsprovidingpermanentfloodprotection,andattentionisdrawntotheneedtoensureasafeevacuationofpersonsintheeventofanemergencyandtoaccessandegressforpersonswithimpairedmovement.Thesefloodprotectionproductsareinstalledoractivatedintheeventofanimminentfloodandremovedordeactivatedassoonasdangerfromfloodingisover.ThisPASisnotapplicabletothetestingoffoamproducts,suchasthosecomposedwithcompositepolyurethane.ThisPASisnotapplicabletofloodprotectionproductsforinstallationaroundbuildings;thesearecoveredbyPAS1188-3.ThisPASisnotapplicabletotemporaryordemountablefloodprotectionproductswhicharedesignedtobeinstalledawayfromandnotattachedtobuildings,includingfloodprotectionproductsintendedforinstallationacrossdrivewayentrancesandgatewaysatpropertyboundaries.ThesearecoveredbyPAS1188-2andPAS1188-4.
【中国标准分类号】:P58
【国际标准分类号】:91_120_99
【页数】:28P.;A4
【正文语种】:英语



版权声明:所有资料均为作者提供或网友推荐收集整理而来,仅供爱好者学习和研究使用,版权归原作者所有。
如本站内容有侵犯您的合法权益,请和我们取得联系,我们将立即改正或删除。